5-5.3 VeriPHY
This section is used for running the VeriPHY Cable Diagnostics. Press to run the diagnostics.
This will take approximately 5 seconds. If all ports are selected, this can take approximately
15 seconds. When completed, the page refreshes automatically, and you can view the cable
diagnostics results in the cable status table. Note that VeriPHY is only accurate for cables of
length 7 -140 meters.10 and 100 Mbps ports will be linked down while running VeriPHY.
Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to
stop responding until VeriPHY is complete.
Web Interface
To configure a VeriPHY Cable Diagnostics Configuration in the web interface:
1. Specify Port which want to check.
2. Click Start.
Figure 5-5.3: The VeriPHY
Parameter description:
Port :
The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status :
Port: Port number.
Pair: The status of the cable pair.
Length: The length (in meters) of the cable pair.