LevelOne GTL-5280 Manual de usuario Pagina 181

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 180
173
The value accepted is within the range of 1-65535. But an appropriate port number not
used by other protocols need to be configured. By default, the port's number is 6343
Time out :
It is the duration during which the collector receives samples, Once it is expired the
sampler stops sending the samples. It is through the management the value is set before it
expires. The value accepted is within the range of 0-2147483647. By default it is set to 0.
Datagram Size :
It is the maximum UDP datagram size to send out the sFlow samples to the receiver. The
value accepted is within the range of 200-1500 bytes. The default is 1400 bytes.
Buttons:
Apply Click to Apply changes.
Reset- Click to undo any changes made locally and revert to previously Saved
values.